Synthes pelvic inventory

Instructions for Use 04.502.021 MatrixNEURO Ultra Low Profile Burr Hole Cover, for burr holes up to B 12.0 mm, thickness 0.3 mm, Pure Titanium.

Aug 24, 2021 · From early attempts of fixation using wires to the emergence of 3D printed plates, this chapter aims to highlight the different plate designs used for pelvis and acetabular fracture surgery. The most common plates currently used for pelvic and acetabular fracture surgery are the reconstruction plates. They can be easily contoured and used for a ...The DePuy Synthes Large External Fixation Systems are intended to provide treatment for long bone and pelvic fractures that require external fixation. Specifically, the components can be used for: • Stabilization of soft tissues and fractures • Polytrauma/multiple orthopaedic trauma • Vertically stable pelvic fractures, or as a treatment ...

Did you know?

Midfoot Fusion Bolt (6.5 mm) Product Codes : 02.111.150, 02.111.150S, 02.111.155... View More. PRODUCT CODES. DESCRIPTION. Our 6.5 mm Midfoot Fusion Bolt is designed for fracture fixation, osteotomies, non-unions, and other fusions of large bones in the foot and ankle. It is available in 50-160 mm lengths with either a stainless steel or ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants P J3266-K 3/11 Inventory Control Form DHS/DCS & DHS/DCS One-Step Insertion plvllllpklgulpu. † NT NT 4 16 mm 212.106 20 mm 212.108 4 4.x NT NT 44 4 4 16 mm 4 18 mm 4 20 mm 4 22 mm 44 4 4mm 4 28 mm 4 30 …Dr. Rahul Vaidya is a paid consultant by Smith and Nephew and Johnson and Johnson/Synthes USA to develop an FDA approved device for the INFIX. The implants depicted are off the shelf implants used in the INFIX method. ... The INFIX procedure for anterior pelvic fixation is based on standard techniques that are familiar to the Orthopaedic Pelvic ...Variable Angle Locking Screw Technology. Variable angle (VA) locking screw technology allows freedom to choose screw trajectory up to 15° in each direction to avoid existing implants, prosthesis, or independent lag screws. A variety of lengths are available which allow for desired spanning of the femur. 4.

Orthopaedic Cable System. The DePuy Synthes Cable System is a cerclage system that consists of two different-sized cerclage cables with crimp in three different materials [Stainless steel, Titanium Alloy, Cobalt Chromium Alloy], and instruments for applying the cable assembly. Product Specifications.According to the NAHB report for March, builders remained cautiously optimistic in April as limited resale inventory helped to increase demand in the new home market. According to ...Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes “Import-ant ...61.503.830, 03.503.034, 03.503.036... View More. PRODUCT CODES. DESCRIPTION. The MatrixMANDIBLE™ Plating System provides internal fixation solutions for mandible trauma and reconstruction procedures. It includes a wide selection of mandible plates and screws. Plates, screws and instruments are color-coded. Get in Touch with a Sales Consultant.and Pelvic C-Clamp Cannulated Nails. Schanz Screws and Steinmann Pins can be used in various anatomical locations in the body based on the external fixation and distraction system being utilized. The Pelvic C-Clamp Cannulated Nails are only used in the pelvic ring. All external fixator implants are single packed. Schanz screws and Steinmann pins

Pelvic Implants and Instruments Periarticular Aiming Arm Instruments for LCP Condylar Plate 4.5/5.0 ... Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain -About This Product. The LCP™ Proximal Tibia Plates are indicated for fractures of the proximal tibia and treatment of nonunions, malunions, and osteopenic bone. They are available in the following options: 3.5 mm LCP Proximal Tibia Plate. 3.5 mm LCP Proximal Tibia Plate – Low Bend. 4.5 mm LCP Proximal Tibia Plate.Inventory Control Form Zero-P Patient Contact: Synthes (USA) To Click: (800) 523-0322 Synthes (Canada) Ltd. To Order: (800) 668-1119 Set: Institution: Surgeon: Procedure: Implantology 3.0 mm Ti. synthes matrix midface inventory control form · synthes css large inventory · synthes usf take · synthes tfna inventory control · synthes pelvic implant ... ….

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Synthes pelvic inventory. Possible cause: Not clear synthes pelvic inventory.

About This Product. The TFN-ADVANCED Nailing System is a part of the Advanced Nailing System from DePuy Synthes and has features that allow surgeons to address proximal femur fractures. The system includes: Long Nails - Diameters: 9-12, & 14 mm. Lengths ranging from: 260 - 480 mm. Short Nails - Diameters: 9-12 mm.Synthes Pelvic Implant Set With Self-Tapping Screws (125.885) Plates 3.5 mm Reconstruction Plates Catalog # Description 245.15 5 Holes (2) ... 306.20 Pelvic Implant Set Graphic Case Catalog # 218.0 Screws 3.5 mm Self-Tapping Screws Catalog # Description 55 55 mm (3) 60 60 mm (3) 65 65 mm (3) 204.670 70 mm (3)2 Synthes LCP Proximal Tibial Plate 3.5 Technique Guide The LCP Proximal Tibial Plate 3.5 is part of the Small Frag-ment LCP System, which merges locking screw technology with conventional plating techniques. The LCP Proximal Tibial Plate 3.5 has a limited-contact profile. The head and neck portions of the plate accept 3.5 mm

11 DePuy Synthes 2.4/2.7 mm Variable Angle LCP ® Two-Column Volar Distal Radius Plate, Extra-Long Surgical Technique. Select the plate according to the fracture pattern and anatomy of the radius. Use the sizing templates to determine the size (width and length) of the plate to be used. Left and right are marked on opposite sides.Inventory Control Form Modular Foot System Implants and Instruments 2.0 mm Cortex Screws, self-tapping Length 201.808 201.810 201.812 201.814 201.816 201.818 201.820 201.822 201.824 3.5 mm Cortex Screws, self-tapping Length 204.810 10 mm 204.812 12 mm 204.814 14 mm 204.816 16 mm 204.818 18 mm 204.820 20 mm 204.822 22 mm 204.824 24 mm 204.826 26 mmA-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA.

tevera vcu login 2.7 MM VA LCP™ CLAVICLE System. Product Codes: 02.112.610, 02.112.611, 02.112.612... View More. PRODUCT CODES. DESCRIPTION. Designed based on an analysis of clavicle CT scans to enhance plate-to-bone fit on a broad range of patients 1 and to treat lateral, shaft and medial fractures for small, medium and large clavicles.Permits rapid reduction and stabilization of the posterior pelvic ring. Description The Pelvic C-Clamp is an emergency stablization instrument for unstable injuries and fractures of the pelvic ring. Unstable pelvic ring fractures can be associated with massive blood loss that can cause terminal shock. The Pelvic C-Clamp allows rapid reduction ... kierra sheard net worthwater temp tampa 6 DePuy Synthes Large Distractor–Femur Surgical Technique Universal Joint Assembly 1 Select a 14.0 mm threaded spindle (A) of appropriate length (most likely 480 mm). A transverse hole will be in the proximal end when applied to the femur. 2 Turn the end piece with double joint (B) onto the threaded pink and white capsule no markings The DePuy Synthes 4.5mm VA-LCP Curved Condylar Plate System has been approved by the FDA for "buttressing multi-fragmentary distal femur fractures including: supracondylar, intra-articular and extra-articular condylar fractures, periprosthetic fractures, fractures in normal or osteopenic bone, and non-unions and malunions." ... mathews hyperlitestony basalt osrsdothan rescue mission store Quick steps to complete and e-sign Synthes Low profile pelvic inventory online: Use Get Form or simply click on the template preview to open it in the editor. Start completing the fillable fields and carefully type in required information. Use the Cross or Check marks in the top toolbar to select your answers in the list boxes. 100 day dream home wikipedia Consult Depuy Synthes's entire 2.4 mm VA LCP™ catalogue on MedicalExpo. Page: 1/4Choose your Location. Last Updated Jun 1, 2023. From this site you can view or print Instructions For Use for DePuy Synthes devices. Manuals should be reviewed before using or implanting a device, or performing follow-up care. lily nails nicevillegdim ucigrand marnier costco INVENTORY CONTROL FORM Case Information (eg, Case ID): Synthes USA Products, LLC To order: (800) 523-0322 Synthes (Canada) Ltd. To order: (800) 668-1119 RIA 2 Reamer Irrigator Aspirator Date: Hospital: Surgeon: Procedure: Y N D Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada.